GScan-600 Microscope Slide Scanner

GScan-600 Microscope Slide Scanner

GScan-600
Fast speed, High precision, Stable
Brightfield
Clinic, training, remote consultation

Description

 

Product Parameters

 

Name

Microscope slide scanner

Item

GScan-600

Capacity

600

Scanning speed

<25s(20X, 15mm*15mm)

<90s(40X, 15mm*15mm)

Resolution

≤0.25μm / pixel (20X)
≤0.125μm / pixel (40X)

Magnification

20X /40X

Objective

20X, NA 0.8; 40X, NA 0.95

Image format

SDPC/TIFF/ SVS

Acceptable slides

1inch x 3inch

Focus mode

Automatic/ manual

Label identification

Linear code / QR code

Dimensions

930*742*817mm

Weight

120kg

 

 Bright-field Scanning

 

Brightfield Scanner

 

Key Advantages

S-shaped scaning

 

Large target camera make scanning faster

S-shaped trajectory scanning method save scanning time and improve scanning accuracy. (fig.A S-shaped scanning, fig.B Others Line scaning,Z-type one-way scanning).CMOS sensor with high resolution and 43 fps acquisition speed.

GCell Technology S-Shaped Scaning

15s(20X 15×15 mm)            

 

High speed Scanner (Ultra-high Precision Motion Control)

Piezoelectric Ceramic Stacked Nano- s tage(fig.C). The self-developed piezoelectric ceramic stacked nano- stage controls the axis, Total stroke >150μm,small signal (20μm stroke,positioning time 40ms)resolution 10nm, fast and precise focus positioning.

GCell Technology Scaning speed

Double Objectives(NA. 0.95)

 

High resolution optical imaging

Self-developed high-speed stroboscopic light source, which instantly provides ultra-high-power illumination(150 flashes/s) through stroboscopic mode,ensuringenough luminous flux,uniform illumination,and clearer imagingduring high-speed scanning.Another feature of the stroboscopic light source is the low temperature effect during long-term work,which has a protective effect on the sample.

GCell Technology double objective

 

      Auto-focus     

 

Dynamic pre-focusing on entire specimen

The GScan series can select focus according to different tissues. Focus check points within a scanned slide are automatically determined. It analyzes focus status right before capturing an image and adjusts the objective lens to focus the image in real time.

GCell Technology Auto-Focus

       Z-stack             

 

Z-stack Extended Focus

lmproves your image quality when analyzing thick samples. Acquiring the high resolution digitized images of thick samples which have 3D structures such as clumps of cells and thick tissues(Approx. 20μm).

GCell Technology Z-Stack Scanning

Automatic system calibration

 

Automatic system calibration

Based on the special database limit compression technology of artificial intelligence algorithm, the storage space and cost are greatly saved without affecting the imaging quality.

GCell Technology Calibration
H&E,IHC,Special Stains

 

Automatic recognition of different slide types

H&E,IHC,Special Stains

Apply to histopathology, tissue section, cell pathology,

TCT exfoliated cell smear, etc

 

Product Characteristic

 

GCell microscope slide scanner is a device used to digitize glass slides containing tissue specimens. Slide digitization has the following benefits, including:
1. Easy to read - make the reading free from the limitations of the microscope, the mouse operation can quickly select any part of the slice for observation, not limited by the field of view under the microscope, its structure is complete, the field of view is comprehensive, the resolution is high, the picture is clear, the color is saturated, and the image is not distorted.
2. Slice preservation - through analysis and statistical software, the digital image analysis and classification of the same kind of pathological slides, search and management is more convenient, efficient and convenient. It avoids that traditional slices are easy to break and fade in the process of production and use, and some precious specimens can be stored for a long time after being transformed into digital slices and are not easy to be lost.
3. Scientific research and analysis - to ensure the consistency of image quality and ensure the accuracy of each analysis data. The software is tuned based on the usage habits of scientific research users, and the results are exported in accordance with the requirements of scientific research articles and reports. Slice preview information can be retrieved at any time. It supports the conversion of panoramic result format to facilitate the generality of result analysis.

 

Product Advantage

 

GCell microscope slide scanner advantage is autofocus, wide-range focal plane fitting, field curvature digital correction. The system features rapid automatic focusing and large-scale focal plane fitting, with digital correction for field curvature. The intelligent selection of the focus position is based on the tissue structure, and the system fits the focus plane of the entire tissue based on the designated focus value. This feature ensures that every field of view is captured with clear imaging. Furthermore, the system allows users to customize the focus points based on the flatness of the tissue, optimizing sample focusing for the best results.

 

Product Application

 

Microscope slide scanners are now commonly used in the field of pathology for accurate diagnosis, sharing of information, and collaboration between medical professionals.

 

Hot Tags: GScan-600 Microscope Slide Scanner, China GScan-600 Microscope Slide Scanner manufacturers, suppliers, Mouse Auditory Brainstem Response Testing System, in vivo imaging system, open field test for mice, Water Maze, locomotor activity test, 8 arm radial maze

You Might Also Like